Defects Index  | Documentation Table of Contents 


98/03/02 DEFECT in program page4


SYMPTOM: large post-fit RMS with discontinuities throughout post-fit plots when processing Feb 28, 1998
PROBLEM: The reference frame, and therefore, the coordinates of all sites change from ITRF94 to ITRF96 on March 1, 1998. In processing the February 28 data, the page4 crosses into March 1 and the station coordinates are appropriate update and estimated parameters are correct. However, when the second, post-fit pass through the data occurs, the station coordinates were not reinitialized resulting in erroneous post-fit plots and RMS.
CORRECTION: In rddata: explicitly re-initialize the station coordinates by resetting the "next update" arrays: nexth() and nextl(). nexth and nextl are passed in the common defined in fsinfo.cm.
FOUND BY: Kass 98/03/02
FIXED BY: Schenewerk 98/03/02 12:40

VERSION: 9803.02
SOURCE: /g1/HPUX.10/Src/Page4 /g1/HPUX.09/Src/Page4
EXECUTABLE: /g1/HPUX.10/Bin /g1/HPUX.09/Bin
NOTES: The estimated parameters and other products were correct; effectively only the post-fit plots were in error. However, because these are used to judge the quality of a solution, the run was appropriately considered to have failed.



980302.page4
June 25, 1999
Steve Hilla