96/02/20 17:00 DEFECT in Page4 SINEX output
SYMPTOM: The eccentricity values being reported in the SINEX files
were incorrect.
PROBLEM: Codeing error.
CORRECTION: Change the code.
FOUND BY: Dr. Tom Herring
FIXED BY: Bill Dillinger
VERSION: 9602.20
SOURCE: sinex.f
EXECUTABLE: page4
NOTES: It is my belief that this problem would only affect individuals
combining SINEX files. The reported results for site coordinates
were correct.
960220.output
June 25, 1999
Steve Hilla